Timers
Autodoor Timer
T01-1
$ 135.00ex-gst
- 12 - 24 VDC
- Lacquer coating
- Removable connectors
- Multi mode
- -
Traffic-light Controller
T02-1
$ TBCex-gst
- 12 - 24 VDC
- Lacquer coating
- Lane fault output
- 2x 10A DC relays
- Adjustable lane timer
fuse boards
Fuse Distribution Board 4
FD01-1
$ TBCex-gst
- 12 - 24 VDC
- 4x 2A Fuses
- Blown fuse relay
- Blown fuse LED
- -
Fuse Distribution Board 8
FD02-1
$ TBCex-gst
- 12 - 24 VDC
- 8x 2A Fuses
- Blown fuse relay
- Blown fuse LED
- -
relays
Fire Relay
F01-1
$ 75.00ex-gst
- 12 - 24 VDC
- 10A Relay
- Separate monitoring relay
- Fire isolate jumper
- -
SPDT Relay
R01-1
$TBCex-gst
- 12 - 24 VDC
- Lacquer coating
- 10A Relay
- Common to + / - jumper
- -
DPDT Relay
R01-2
$TBCex-gst
- 12 - 24 VDC
- Lacquer coating
- 10A Relay
- Common to + / - jumper
- -
BDB values your feedback. If you have a suggestion on how we can improve our products or have an idea for a new product, please email us at admin@bdb.co.nz
close

Autodoor Timer
Order ref: T01-1
$ 135NZD ex-gst
- 12 - 24 VDC
- Lacquer coating
- Removable connectors
- Multi mode
- 12-month warranty
The Autodoor timer is a control module for automatic doors, gates, and actuators that require separate commands for opening and locking. It's triggered by a single relay from an access control system. Once activated, the timer releases the lock and sends a momentary pulse to the open input, initiating the door's automatic opening sequence.

Traffic-light Controller
Order ref: T02-1
$ TBCNZD ex-gst
- 12 - 24 VDC
- Lacquer coating
- Lane fault output
- 2x 10A DC relays
- Adjustable lane timer
The adjustable lane timer is a traffic control system designed for a narrow entrance. It uses sensors and traffic lights at both ends of a single lane to manage traffic flow and prevent collisions. When a sensor is triggered, the system initiates a timed sequence, activating the appropriate traffic light to grant right-of-way.
The system includes a blocked lane output that activates if a sensor remains triggered for an excessive duration. This feature allows for the detection and reporting of operational faults, such as a vehicle being stalled within the lane.
The system includes a blocked lane output that activates if a sensor remains triggered for an excessive duration. This feature allows for the detection and reporting of operational faults, such as a vehicle being stalled within the lane.

Fuse Distribution Board 4
Order ref: FD01-1
$ TBCNZD ex-gst
- 12 - 24 VDC
- 4x 2A Fuses
- Blown fuse relay
- Blown fuse LED
- -
The Fused Distribution Board is designed to protect your power supply and connected field devices from overcurrent / short circuit events. It features individually fused outputs, each rated at 2A.
For enhanced reliability and monitoring, a fault-reporting relay is integrated into the board. If any fuse under load blows, the relay is activated, which can be wired into a central alarm system for monitoring. Each fuse also has an associated blown fuse LED indicator for immediate visual identification.
For enhanced reliability and monitoring, a fault-reporting relay is integrated into the board. If any fuse under load blows, the relay is activated, which can be wired into a central alarm system for monitoring. Each fuse also has an associated blown fuse LED indicator for immediate visual identification.

Fuse Distribution Board 8
Order ref: FD02-1
$ TBCNZD ex-gst
- 12 - 24 VDC
- 8x 2A Fuses
- Blown fuse relay
- Blown fuse LED
- -
The Fused Distribution Board is designed to protect your power supply and connected field devices from overcurrent / short circuit events. It features individually fused outputs, each rated at 2A.
For enhanced reliability and monitoring, a fault-reporting relay is integrated into the board. If any fuse under load blows, the relay is activated, which can be wired into a central alarm system for monitoring. Each fuse also has an associated blown fuse LED indicator for immediate visual identification.
For enhanced reliability and monitoring, a fault-reporting relay is integrated into the board. If any fuse under load blows, the relay is activated, which can be wired into a central alarm system for monitoring. Each fuse also has an associated blown fuse LED indicator for immediate visual identification.

Fire Relay
Order ref: F01-1
$TBCNZD ex-gst
- 12 - 24 VDC
- 10A Relay
- Separate monitoring relay
- Fire isolate jumper
- -
This fire relay integrates with an access control system to provide a reliable fire release mechanism. When the fire contact is shorted, the 10A DC contacts are activated, feeding power to your door's fuse distribution board, a fire activation cuts power ensuring that the doors unlock for emergency egress.

SPDT Relay
Order ref: R01-1
$TBCNZD ex-gst
- 12 - 24 VDC
- Lacquer coating
- 10A Relay
- Common to + / - jumper
- -
This versatile relay board is designed for a wide range of applications, accepting either 12V DC or 24V DC input. The single pole relay is rated for switching up to 10A, making it suitable for controlling various circuits and devices.
To ensure long-term reliability in challenging conditions, the circuit board is protected by a lacquer coating. This protective layer safeguards the components from corrosion and moisture, allowing the board to operate reliably in harsh environments.
To ensure long-term reliability in challenging conditions, the circuit board is protected by a lacquer coating. This protective layer safeguards the components from corrosion and moisture, allowing the board to operate reliably in harsh environments.

DPDT Relay
Order ref: R01-2
$TBCNZD ex-gst
- 12 - 24 VDC
- Lacquer coating
- 10A Relay
- Common to + / - jumper
- -
This versatile relay board is designed for a wide range of applications, accepting either 12V DC or 24V DC input. The double pole relay is rated for switching up to 10A, making it suitable for controlling various circuits and devices.
To ensure long-term reliability in challenging conditions, the circuit board is protected by a lacquer coating. This protective layer safeguards the components from corrosion and moisture, allowing the board to operate reliably in harsh environments.